High-Efficiency RO Membranes for Modern Water Systems — 8040 & 4040 Solutions

Why Choose TFC RO Membranes (4040 & 8040)?

  • High Salt Rejection: TFC membranes are proven to remove the vast majority of dissolved salts and contaminants, delivering process- and drinking-grade permeate.

  • Versatile Sizing: The 4040 (4″×40″) is ideal for modular, compact systems and easy parallel scaling. The 8040 (8″×40″) provides large-area throughput for industrial and centralized plants.

  • Cost-Effective Operation: Optimized for good flux at moderate pressures, reducing pump energy costs while maintaining high rejection.

  • OEM & Replacement Friendly: Available as OEM-labeled or compatibility-listed replacements for mainstream brands, simplifying retrofits.

  • Durability with Maintenance: When used with correct pre-treatment (sediment/carbon/softening where needed) and routine chemical cleaning, TFC elements provide predictable life cycles.


Product Overview — Quick Specs (Ready for Your Datasheet)

4040 RO Membrane (Compact & Scalable)

  • Size: 4″×40″ (≈100 mm × 1016 mm)

  • Nominal Permeate (typical, standard test): 800–1,200 GPD (varies with feedwater & pressure)

  • Typical Salt Rejection: ≥ 98%

  • Recommended Use: Small-to-medium commercial systems, labs, modular skids, point-of-entry plants

8040 RO Membrane (High-Capacity & Efficient)

  • Size: 8″×40″ (≈203 mm × 1016 mm)

  • Nominal Permeate (typical, standard test): 3,000–4,000 GPD (varies with feedwater & pressure)

  • Typical Salt Rejection: ≥ 98–99%

  • Recommended Use: Centralized plants, industrial process water, desalination pre-treatment, high-capacity commercial systems

Common Attributes

  • Material: Thin Film Composite (TFC)

  • Design: Spiral-wound element

  • Operating pH (short-term): 2–11 (observe cleaning limits)

  • Max Temp: ≤ 45°C (recommended operating ≤ 35°C for longevity)

  • Chlorine Sensitivity: Must be dechlorinated prior to contact (TFC is chlorine-sensitive)


How to Select Between 4040 and 8040

  1. Daily Capacity Needs: For under ~4 m³/day, 4040 units in parallel can be economical. For multi-ton/day throughput, 8040 reduces the number of housings and simplifies piping.

  2. Footprint and Maintenance: 4040 modules are easier to handle and replace; 8040 reduces the number of replacements and shortens skid lengths in large systems.

  3. System Type: New large plants typically choose 8040 for efficiency; retrofit or modular units often favor 4040 for flexibility.

  4. Feedwater Quality: High TDS or fouling potential calls for conservative recovery and stronger pre-treatment regardless of membrane size.


Practical Installation & Operation Tips

  • Always Pre-treat & Dechlorinate: Protect TFC membranes from particulate fouling and chlorine damage with proper filtration and activated carbon.

  • Monitor Key Indicators: Track permeate conductivity, differential pressure (ΔP) across the membrane, and permeate flow—these are early indicators of fouling or scaling.

  • Schedule Preventive Cleaning: Implement acid/alkali cleaning procedures recommended by the membrane supplier. Maintain cleaning logs to optimize intervals.

  • Avoid Dry-Running: Never subject membranes to dry conditions during transport or installation; always follow manufacturer wetting/flush procedures on first start-up.


Buyer-Focused Value Propositions

  • Wholesale & OEM Availability: Competitive pricing for bulk orders, private-label packaging, and flexible MOQs.

  • Compatibility Checks: Provide your existing model numbers and we’ll confirm fit for retrofit or replacement.

  • Technical Support & Documentation: Datasheets, QA certificates, and cleaning protocols supplied with orders — plus pre-sales engineering assistance.

  • Sample & Trial Options: Small-quantity trials available to validate performance in your site conditions before full procurement.


FAQ — Quick Answers Buyers Want

Q: Can these membranes replace major brand elements?
A: Yes. We offer compatible options for many mainstream brands. Share your current part number for a match.

Q: What life expectancy should I plan for?
A: Typical in-service life is 1–5 years based on feedwater condition, recovery rates, and cleaning rigor.

Q: Do you ship worldwide and support customs documentation?
A: Yes. We support international shipping, HS codes, and can provide necessary certificates for customs clearance.

Q: How do I request samples or pricing?
A: Contact sales with model (4040/8040), quantity, desired labeling, and destination port for an immediate quote.


Call to Action — Start Your Inquiry Today

Ready to reduce operational headaches and get reliable permeate quality? Request a quote or sample now. Provide your application details (feedwater TDS, daily capacity target, existing housings if retrofitting) and we’ll respond with recommended models, pricing, and lead times.

Contact Sales: sales@yourcompany.com | WhatsApp/WeChat: +86-123-456-7890 | Alibaba Inquiry Button


SEO & Posting Tips (One-Minute Checklist)

  • Place the primary keywords in the title, H1, and within the first 100 words: RO membrane, 4040 RO membrane, 8040 RO membrane, TFC RO membrane.

  • Add a downloadable PDF datasheet (include test conditions and normalized flux data).

  • Use product schema (Product + Offer) on the page with SKU and price range.

  • Include alt text for images: e.g., “4040 RO membrane element TFC”, “8040 spiral-wound RO membrane”.

  • Link to related pages (pre-treatment, cleaning chemicals, full RO systems) to improve internal SEO flow.




   
Request a Quote
Our experts are here to help. We will respond within 24 hours to your request.
   
Get in Touch with Us
Monday - Friday 8:00 am - 5:00 pm (CST)
(86) 13803219803 - phone
86-311-89681588 - tel
sales6@incefiltration.com
   
Request a Sample
Need a closer look? Most products have samples available to ensure you are ordering the correct product for your needs. Some restrictions may apply.

Leave a message
X
Tell us what you need, and we'll help you get quotes.Our Email:sales6@incefiltration.com
THE 19TH INTERNATIONAL EXHIBITIONWATER AND WASTEWATERTECHNOLOGY AND EQUIPMENT