High-Efficiency RO Membranes for Modern Water Systems — 8040 & 4040 Solutions
Why Choose TFC RO Membranes (4040 & 8040)?
-
High Salt Rejection: TFC membranes are proven to remove the vast majority of dissolved salts and contaminants, delivering process- and drinking-grade permeate.
-
Versatile Sizing: The 4040 (4″×40″) is ideal for modular, compact systems and easy parallel scaling. The 8040 (8″×40″) provides large-area throughput for industrial and centralized plants.
-
Cost-Effective Operation: Optimized for good flux at moderate pressures, reducing pump energy costs while maintaining high rejection.
-
OEM & Replacement Friendly: Available as OEM-labeled or compatibility-listed replacements for mainstream brands, simplifying retrofits.
-
Durability with Maintenance: When used with correct pre-treatment (sediment/carbon/softening where needed) and routine chemical cleaning, TFC elements provide predictable life cycles.
Product Overview — Quick Specs (Ready for Your Datasheet)
4040 RO Membrane (Compact & Scalable)
-
Size: 4″×40″ (≈100 mm × 1016 mm)
-
Nominal Permeate (typical, standard test): 800–1,200 GPD (varies with feedwater & pressure)
-
Typical Salt Rejection: ≥ 98%
-
Recommended Use: Small-to-medium commercial systems, labs, modular skids, point-of-entry plants
8040 RO Membrane (High-Capacity & Efficient)
-
Size: 8″×40″ (≈203 mm × 1016 mm)
-
Nominal Permeate (typical, standard test): 3,000–4,000 GPD (varies with feedwater & pressure)
-
Typical Salt Rejection: ≥ 98–99%
-
Recommended Use: Centralized plants, industrial process water, desalination pre-treatment, high-capacity commercial systems
Common Attributes
-
Material: Thin Film Composite (TFC)
-
Design: Spiral-wound element
-
Operating pH (short-term): 2–11 (observe cleaning limits)
-
Max Temp: ≤ 45°C (recommended operating ≤ 35°C for longevity)
-
Chlorine Sensitivity: Must be dechlorinated prior to contact (TFC is chlorine-sensitive)
How to Select Between 4040 and 8040
-
Daily Capacity Needs: For under ~4 m³/day, 4040 units in parallel can be economical. For multi-ton/day throughput, 8040 reduces the number of housings and simplifies piping.
-
Footprint and Maintenance: 4040 modules are easier to handle and replace; 8040 reduces the number of replacements and shortens skid lengths in large systems.
-
System Type: New large plants typically choose 8040 for efficiency; retrofit or modular units often favor 4040 for flexibility.
-
Feedwater Quality: High TDS or fouling potential calls for conservative recovery and stronger pre-treatment regardless of membrane size.
Practical Installation & Operation Tips
-
Always Pre-treat & Dechlorinate: Protect TFC membranes from particulate fouling and chlorine damage with proper filtration and activated carbon.
-
Monitor Key Indicators: Track permeate conductivity, differential pressure (ΔP) across the membrane, and permeate flow—these are early indicators of fouling or scaling.
-
Schedule Preventive Cleaning: Implement acid/alkali cleaning procedures recommended by the membrane supplier. Maintain cleaning logs to optimize intervals.
-
Avoid Dry-Running: Never subject membranes to dry conditions during transport or installation; always follow manufacturer wetting/flush procedures on first start-up.
Buyer-Focused Value Propositions
-
Wholesale & OEM Availability: Competitive pricing for bulk orders, private-label packaging, and flexible MOQs.
-
Compatibility Checks: Provide your existing model numbers and we’ll confirm fit for retrofit or replacement.
-
Technical Support & Documentation: Datasheets, QA certificates, and cleaning protocols supplied with orders — plus pre-sales engineering assistance.
-
Sample & Trial Options: Small-quantity trials available to validate performance in your site conditions before full procurement.
FAQ — Quick Answers Buyers Want
Q: Can these membranes replace major brand elements?
A: Yes. We offer compatible options for many mainstream brands. Share your current part number for a match.
Q: What life expectancy should I plan for?
A: Typical in-service life is 1–5 years based on feedwater condition, recovery rates, and cleaning rigor.
Q: Do you ship worldwide and support customs documentation?
A: Yes. We support international shipping, HS codes, and can provide necessary certificates for customs clearance.
Q: How do I request samples or pricing?
A: Contact sales with model (4040/8040), quantity, desired labeling, and destination port for an immediate quote.
Call to Action — Start Your Inquiry Today
Ready to reduce operational headaches and get reliable permeate quality? Request a quote or sample now. Provide your application details (feedwater TDS, daily capacity target, existing housings if retrofitting) and we’ll respond with recommended models, pricing, and lead times.
Contact Sales: sales@yourcompany.com | WhatsApp/WeChat: +86-123-456-7890 | Alibaba Inquiry Button
SEO & Posting Tips (One-Minute Checklist)
-
Place the primary keywords in the title, H1, and within the first 100 words: RO membrane, 4040 RO membrane, 8040 RO membrane, TFC RO membrane.
-
Add a downloadable PDF datasheet (include test conditions and normalized flux data).
-
Use product schema (Product + Offer) on the page with SKU and price range.
-
Include alt text for images: e.g., “4040 RO membrane element TFC”, “8040 spiral-wound RO membrane”.
-
Link to related pages (pre-treatment, cleaning chemicals, full RO systems) to improve internal SEO flow.